The Rheem RTG20212BG Flame Rod FL2 is a direct replacement component engineered to provide flame verification within select Rheem, Ruud, and Richmond tankless gas water heaters. This sensor works in coordination with the ignition control board to confirm flame presence through rectification, ensuring proper burner operation and immediate gas shutoff if no flame is detected.
This assembly includes the flame rod, pre-attached wire lead, and OEM-specified gasket to ensure a correct seal at the combustion interface. Proper installation of this sensor is critical for maintaining operational safety, system reliability, and compliance with flame safety protocols.
During ignition, the RTG20212BG detects flame via ionization. If flame signal is absent or intermittent, the control board initiates lockout or retry sequences (e.g., error code 11). Flame signal strength is dependent on proper probe positioning, electrical integrity, and combustion quality. Replacement is recommended during routine service intervals or when diagnosis indicates flame sensing failure.
Installation should be performed with gas and power disconnected. Remove the access panel and combustion chamber cover to reach the flame rod mounting port. Install the sensor with the supplied gasket to maintain a sealed combustion environment. Route and connect the lead wire to the control board terminal as specified in the unit’s service manual. Verify signal strength through onboard diagnostics after installation.
Recommended | 5417 |
---|---|
Brand | Rheem |
Manufacturer Part Number | RTG20212BG |
Warranty | 1 Year |
Item Type | Water Heater Parts |
Item Returns | This item can be returned |